Hazardous work zones (i.e., hot, warm, and cold) are typically established by emergency response teams during hazardous materials (HAZMAT) calls but less consistently for fire responses to segment personnel and response activities in the immediate geographic area around the fire. Despite national guidelines, studies have documented the inconsistent use of respiratory protective equipment by firefighters at the fire scene. In this case-series report, we describe warm zone gas levels using multigas detectors across five independent fire incident responses all occurring in a large South Florida fire department. Multigas detector data collected at each fire response indicate the presence of sustained levels of volatile organic compounds in the “warm zone” of each fire event. These cases suggest that firefighters should not only implement strategies for multigas detector use within the warm zone but also include respiratory protection to provide adequate safety from toxic exposures in the warm zone.

Original languageEnglish
Pages (from-to)352-355
Number of pages4
JournalSafety and Health at Work
Volume9
Issue number3
DOIs
StatePublished - 1 Sep 2018

Fingerprint

Firefighters
Environmental Monitoring
incident
Fires
monitoring
Monitoring
fire department
Detectors
hazardous material
Hazardous Substances
Volatile Organic Compounds
Hazardous materials
personnel
Poisons
Volatile organic compounds
event
Emergencies
Gases
Personnel
Guidelines

Keywords

  • Firefighters
  • Multigas detectors
  • Respiratory protection
  • Warm zone

Cite this

Caban-Martinez, A. J., Kropa, B., Niemczyk, N., Moore, K. J., Baum, J., Solle, N. S., ... Kobetz, E. N. (2018). The “Warm Zone” Cases: Environmental Monitoring Immediately Outside the Fire Incident Response Arena by Firefighters. Safety and Health at Work, 9(3), 352-355. https://doi.org/10.1016/j.shaw.2017.12.003
Caban-Martinez, Alberto J. ; Kropa, Bob ; Niemczyk, Neal ; Moore, Kevin J. ; Baum, Jeramy ; Solle, Natasha Schaefer ; Sterling, David ; Kobetz, Erin N. / The “Warm Zone” Cases : Environmental Monitoring Immediately Outside the Fire Incident Response Arena by Firefighters. In: Safety and Health at Work. 2018 ; Vol. 9, No. 3. pp. 352-355.
@article{76d2e4494bb94144aa58d6f3168cc110,
title = "The “Warm Zone” Cases: Environmental Monitoring Immediately Outside the Fire Incident Response Arena by Firefighters",
abstract = "Hazardous work zones (i.e., hot, warm, and cold) are typically established by emergency response teams during hazardous materials (HAZMAT) calls but less consistently for fire responses to segment personnel and response activities in the immediate geographic area around the fire. Despite national guidelines, studies have documented the inconsistent use of respiratory protective equipment by firefighters at the fire scene. In this case-series report, we describe warm zone gas levels using multigas detectors across five independent fire incident responses all occurring in a large South Florida fire department. Multigas detector data collected at each fire response indicate the presence of sustained levels of volatile organic compounds in the “warm zone” of each fire event. These cases suggest that firefighters should not only implement strategies for multigas detector use within the warm zone but also include respiratory protection to provide adequate safety from toxic exposures in the warm zone.",
keywords = "Firefighters, Multigas detectors, Respiratory protection, Warm zone",
author = "Caban-Martinez, {Alberto J.} and Bob Kropa and Neal Niemczyk and Moore, {Kevin J.} and Jeramy Baum and Solle, {Natasha Schaefer} and David Sterling and Kobetz, {Erin N.}",
year = "2018",
month = "9",
day = "1",
doi = "10.1016/j.shaw.2017.12.003",
language = "English",
volume = "9",
pages = "352--355",
journal = "Safety and Health at Work",
issn = "2093-7911",
publisher = "Elsevier BV",
number = "3",

}

The “Warm Zone” Cases : Environmental Monitoring Immediately Outside the Fire Incident Response Arena by Firefighters. / Caban-Martinez, Alberto J.; Kropa, Bob; Niemczyk, Neal; Moore, Kevin J.; Baum, Jeramy; Solle, Natasha Schaefer; Sterling, David; Kobetz, Erin N.

In: Safety and Health at Work, Vol. 9, No. 3, 01.09.2018, p. 352-355.

Research output: Contribution to journalArticleResearchpeer-review

TY - JOUR

T1 - The “Warm Zone” Cases

T2 - Environmental Monitoring Immediately Outside the Fire Incident Response Arena by Firefighters

AU - Caban-Martinez, Alberto J.

AU - Kropa, Bob

AU - Niemczyk, Neal

AU - Moore, Kevin J.

AU - Baum, Jeramy

AU - Solle, Natasha Schaefer

AU - Sterling, David

AU - Kobetz, Erin N.

PY - 2018/9/1

Y1 - 2018/9/1

N2 - Hazardous work zones (i.e., hot, warm, and cold) are typically established by emergency response teams during hazardous materials (HAZMAT) calls but less consistently for fire responses to segment personnel and response activities in the immediate geographic area around the fire. Despite national guidelines, studies have documented the inconsistent use of respiratory protective equipment by firefighters at the fire scene. In this case-series report, we describe warm zone gas levels using multigas detectors across five independent fire incident responses all occurring in a large South Florida fire department. Multigas detector data collected at each fire response indicate the presence of sustained levels of volatile organic compounds in the “warm zone” of each fire event. These cases suggest that firefighters should not only implement strategies for multigas detector use within the warm zone but also include respiratory protection to provide adequate safety from toxic exposures in the warm zone.

AB - Hazardous work zones (i.e., hot, warm, and cold) are typically established by emergency response teams during hazardous materials (HAZMAT) calls but less consistently for fire responses to segment personnel and response activities in the immediate geographic area around the fire. Despite national guidelines, studies have documented the inconsistent use of respiratory protective equipment by firefighters at the fire scene. In this case-series report, we describe warm zone gas levels using multigas detectors across five independent fire incident responses all occurring in a large South Florida fire department. Multigas detector data collected at each fire response indicate the presence of sustained levels of volatile organic compounds in the “warm zone” of each fire event. These cases suggest that firefighters should not only implement strategies for multigas detector use within the warm zone but also include respiratory protection to provide adequate safety from toxic exposures in the warm zone.

KW - Firefighters

KW - Multigas detectors

KW - Respiratory protection

KW - Warm zone

UR - http://www.scopus.com/inward/record.url?scp=85041628237&partnerID=8YFLogxK

U2 - 10.1016/j.shaw.2017.12.003

DO - 10.1016/j.shaw.2017.12.003

M3 - Article

VL - 9

SP - 352

EP - 355

JO - Safety and Health at Work

JF - Safety and Health at Work

SN - 2093-7911

IS - 3

ER -