Polarization-based sensing with a self-referenced sample

Joseph R. Lakowicz, Ignacy Gryczynski, Zygmunt Gryczynski, Leah Tolosa, Jonathan D. Dattelbaum, Govind Rao

Research output: Contribution to journalArticle

12 Citations (Scopus)

Abstract

We describe a new method of fluorescence sensing based on fluorescence polarization. The sensor consists of two compartments, both of which contain the sensing fluorophore. One side of the sensor contains a constant concentration of analyte, an the other contains the unknown concentration. Emission from both sides is observed through polarizers, with the polarization from the sample being rotated 90° from that of the reference. Changes in the fluorescence intensity of the sample result in changes in the measured polarization for the combined emission. We show that this approach can be used to measure glucose and calcium using fluorophores which show analyte-dependent intensity changes, and no change in the spectral shape. Only a single fluorophore is required, this being the sensing fluorophore in both sides of the sensor. We also show that polarization sensing of glucose and calcium can be performed with visual detection of the polarization. In this case the only electronic component is the light source. These simple schemes can be used with a variety of analytes. The only requirement is a change in fluorescence intensity in response to the analyte.

Original languageEnglish
Pages (from-to)1149-1157
Number of pages9
JournalApplied Spectroscopy
Volume53
Issue number9
DOIs
StatePublished - 1 Sep 1999

Fingerprint

Fluorophores
Polarization
Fluorescence
polarization
fluorescence
glucose
Glucose
calcium
Calcium
sensors
Sensors
compartments
polarizers
Light sources
light sources
requirements
electronics

Cite this

Lakowicz, Joseph R. ; Gryczynski, Ignacy ; Gryczynski, Zygmunt ; Tolosa, Leah ; Dattelbaum, Jonathan D. ; Rao, Govind. / Polarization-based sensing with a self-referenced sample. In: Applied Spectroscopy. 1999 ; Vol. 53, No. 9. pp. 1149-1157.
@article{5b46caab5fac4f94975a53b7fdae12a6,
title = "Polarization-based sensing with a self-referenced sample",
abstract = "We describe a new method of fluorescence sensing based on fluorescence polarization. The sensor consists of two compartments, both of which contain the sensing fluorophore. One side of the sensor contains a constant concentration of analyte, an the other contains the unknown concentration. Emission from both sides is observed through polarizers, with the polarization from the sample being rotated 90° from that of the reference. Changes in the fluorescence intensity of the sample result in changes in the measured polarization for the combined emission. We show that this approach can be used to measure glucose and calcium using fluorophores which show analyte-dependent intensity changes, and no change in the spectral shape. Only a single fluorophore is required, this being the sensing fluorophore in both sides of the sensor. We also show that polarization sensing of glucose and calcium can be performed with visual detection of the polarization. In this case the only electronic component is the light source. These simple schemes can be used with a variety of analytes. The only requirement is a change in fluorescence intensity in response to the analyte.",
author = "Lakowicz, {Joseph R.} and Ignacy Gryczynski and Zygmunt Gryczynski and Leah Tolosa and Dattelbaum, {Jonathan D.} and Govind Rao",
year = "1999",
month = "9",
day = "1",
doi = "10.1366/0003702991947964",
language = "English",
volume = "53",
pages = "1149--1157",
journal = "Applied Spectroscopy",
issn = "0003-7028",
publisher = "SAGE Publications Inc.",
number = "9",

}

Polarization-based sensing with a self-referenced sample. / Lakowicz, Joseph R.; Gryczynski, Ignacy; Gryczynski, Zygmunt; Tolosa, Leah; Dattelbaum, Jonathan D.; Rao, Govind.

In: Applied Spectroscopy, Vol. 53, No. 9, 01.09.1999, p. 1149-1157.

Research output: Contribution to journalArticle

TY - JOUR

T1 - Polarization-based sensing with a self-referenced sample

AU - Lakowicz, Joseph R.

AU - Gryczynski, Ignacy

AU - Gryczynski, Zygmunt

AU - Tolosa, Leah

AU - Dattelbaum, Jonathan D.

AU - Rao, Govind

PY - 1999/9/1

Y1 - 1999/9/1

N2 - We describe a new method of fluorescence sensing based on fluorescence polarization. The sensor consists of two compartments, both of which contain the sensing fluorophore. One side of the sensor contains a constant concentration of analyte, an the other contains the unknown concentration. Emission from both sides is observed through polarizers, with the polarization from the sample being rotated 90° from that of the reference. Changes in the fluorescence intensity of the sample result in changes in the measured polarization for the combined emission. We show that this approach can be used to measure glucose and calcium using fluorophores which show analyte-dependent intensity changes, and no change in the spectral shape. Only a single fluorophore is required, this being the sensing fluorophore in both sides of the sensor. We also show that polarization sensing of glucose and calcium can be performed with visual detection of the polarization. In this case the only electronic component is the light source. These simple schemes can be used with a variety of analytes. The only requirement is a change in fluorescence intensity in response to the analyte.

AB - We describe a new method of fluorescence sensing based on fluorescence polarization. The sensor consists of two compartments, both of which contain the sensing fluorophore. One side of the sensor contains a constant concentration of analyte, an the other contains the unknown concentration. Emission from both sides is observed through polarizers, with the polarization from the sample being rotated 90° from that of the reference. Changes in the fluorescence intensity of the sample result in changes in the measured polarization for the combined emission. We show that this approach can be used to measure glucose and calcium using fluorophores which show analyte-dependent intensity changes, and no change in the spectral shape. Only a single fluorophore is required, this being the sensing fluorophore in both sides of the sensor. We also show that polarization sensing of glucose and calcium can be performed with visual detection of the polarization. In this case the only electronic component is the light source. These simple schemes can be used with a variety of analytes. The only requirement is a change in fluorescence intensity in response to the analyte.

UR - http://www.scopus.com/inward/record.url?scp=0033184744&partnerID=8YFLogxK

U2 - 10.1366/0003702991947964

DO - 10.1366/0003702991947964

M3 - Article

AN - SCOPUS:0033184744

VL - 53

SP - 1149

EP - 1157

JO - Applied Spectroscopy

JF - Applied Spectroscopy

SN - 0003-7028

IS - 9

ER -