Long lived BSA Au clusters as a time gated intensity imaging probe

Research output: Contribution to journalArticleResearchpeer-review

20 Citations (Scopus)

Abstract

The work presented here reports the use of long lifetime (>1 μs) BSA Au clusters as a cellular/tissue, time gated, intensity imaging probe. By collecting the emission signal 50 ns post excitation, one can off-gate the intense auto-fluorescence background, thereby greatly enhancing the clarity/specificity in fluorescence imaging.

Original languageEnglish
Pages (from-to)2594-2597
Number of pages4
JournalNanoscale
Volume6
Issue number5
DOIs
StatePublished - 7 Mar 2014

Fingerprint

Fluorescence
Imaging techniques
Tissue

Cite this

@article{d1d4a7c662734d1e9d13f75d7acc5153,
title = "Long lived BSA Au clusters as a time gated intensity imaging probe",
abstract = "The work presented here reports the use of long lifetime (>1 μs) BSA Au clusters as a cellular/tissue, time gated, intensity imaging probe. By collecting the emission signal 50 ns post excitation, one can off-gate the intense auto-fluorescence background, thereby greatly enhancing the clarity/specificity in fluorescence imaging.",
author = "Raut, {Sangram Limbaji} and Rafal Fudala and R. Rich and Kokate, {R. A.} and R. Chib and Zygmunt Gryczynski and Ignacy Gryczynski",
year = "2014",
month = "3",
day = "7",
doi = "10.1039/c3nr05692a",
language = "English",
volume = "6",
pages = "2594--2597",
journal = "Nanoscale",
issn = "2040-3364",
publisher = "Royal Society of Chemistry",
number = "5",

}

Long lived BSA Au clusters as a time gated intensity imaging probe. / Raut, Sangram Limbaji; Fudala, Rafal; Rich, R.; Kokate, R. A.; Chib, R.; Gryczynski, Zygmunt; Gryczynski, Ignacy.

In: Nanoscale, Vol. 6, No. 5, 07.03.2014, p. 2594-2597.

Research output: Contribution to journalArticleResearchpeer-review

TY - JOUR

T1 - Long lived BSA Au clusters as a time gated intensity imaging probe

AU - Raut, Sangram Limbaji

AU - Fudala, Rafal

AU - Rich, R.

AU - Kokate, R. A.

AU - Chib, R.

AU - Gryczynski, Zygmunt

AU - Gryczynski, Ignacy

PY - 2014/3/7

Y1 - 2014/3/7

N2 - The work presented here reports the use of long lifetime (>1 μs) BSA Au clusters as a cellular/tissue, time gated, intensity imaging probe. By collecting the emission signal 50 ns post excitation, one can off-gate the intense auto-fluorescence background, thereby greatly enhancing the clarity/specificity in fluorescence imaging.

AB - The work presented here reports the use of long lifetime (>1 μs) BSA Au clusters as a cellular/tissue, time gated, intensity imaging probe. By collecting the emission signal 50 ns post excitation, one can off-gate the intense auto-fluorescence background, thereby greatly enhancing the clarity/specificity in fluorescence imaging.

UR - http://www.scopus.com/inward/record.url?scp=84894657978&partnerID=8YFLogxK

U2 - 10.1039/c3nr05692a

DO - 10.1039/c3nr05692a

M3 - Article

VL - 6

SP - 2594

EP - 2597

JO - Nanoscale

JF - Nanoscale

SN - 2040-3364

IS - 5

ER -